Pyronix PCX 46 Engineer Reference Manual page 14

Hide thumbs Also See for PCX 46:
Table of Contents

Advertisement

No.
Output Type
0000
Not Used
0001
Fire
0002
PA Any
0003
Burglary Any
0004
Final Arm All
0005
Open After Alarm
(Abort)
0007
Tamper Any
0008
Duress Any
0009
PA Device Any
0010
Gas
0011
Arm Fail
0012
Entry Deviation
0013
System Ready Any
0014
Bell Any
0016
Strobe Any
0017
Bypass Rearm Any
0018
Burglary Any
0019
Ready All
0020
Exit Starts All
0021
Exit Starts Any
0022
Final Arm Any
0023
Strobe if Arm Fail
0024
Unable to Arm
0025
Keyswitch Disarm
0026
Arm with Bypass
0027
Pulsed Burglary Any
0028
Power Fault
0031
Entry
0032
Exit
0033
Entry / Exit
0034
Lights
0035
Follow Input
0036
Shunt Fault
0037
Restore 1
0038
Restore 2
0039
PIR Latch 1
0040
PIR Latch 2
PCX 46 Programming Reference
Active
At fire alarm activation
At personal attack activation
At burglary alarm from any area
When ALL areas are armed
When system is silenced after 'burglary'
alarm has been activated
Tamper alarm in any area
At a Duress alarm in any area
At alarm on a PA input only from any
area. (This does not include the keypad
PA)
At gas alarm
Pre-set time after start of exit time, if
exit procedure is not complete
When deviation from entry route occurs,
during entry time
When any of the inputs but the Entry
Delay and Follow are closed
After alarm in any area
After alarm in any area
When inputs are bypassed at rearm in
any area. Turned on after 1st alarm if
active when rearmed
At Burglary alarm in any area
When all inputs but the Entry Delay and
Follow are closed
At start of exit time to arm LAST area
When exit time starts to arm FIRST area
When ANY area has been armed
Works similar to output 016, but also fires if the arm fail timer expires.
This output turns on for 5 seconds when the system is disarmed via a keyswitch
input (either pulsed or latched keyswitch)*
Output activates when an arming procedure is completed with inputs bypassed.
Active when the system is armed with an input bypassed.
Active when burglary alarm is triggered, but deactivates once the Pulsed
Intruder timer has expired (see Program Timers).
Active during low volts and battery faults. Restores at code entry after fault
cleared.
Active during any Entry time
Active during any Exit time
Active during any entry or exit time
When exit or entry timer starts
Active when a specific input number has been activated. It allows the following
options to be programmed:
Follow Type (Follow, Timed, Latched, Code Reset);
Follow What (Input, Shunt List, Sub-Area, Area);
Follow When (Always, When Armed, When Disarmed);
Input to Follow (between 1 to 64)
This input activates if someone tries to shunt an input group where some of the
inputs allocated to this group are open.
At code entry to arm. The normal state
of this input is 0v and it changes to 12v
when activated.
Activates whenever an additional area is
armed. The normal state of this input is
0v and it changes to 12v when activated.
When armed (and in Walk Test)
This is the inverse polarity to
PIR Latch 1
Page: 14
Restore
When a valid code is entered
When a valid code is entered
At first valid code entry
At code entry to disarm
After 2 minutes
At code entry to silence
When a valid code is entered
When a valid code is entered
When a valid code is entered
At code entry to rearm
At code entry to disarm
If fault exists, and after final arm
When alarm silenced or when siren
timer expires
When disarmed or when strobe timer
expires
When system disarmed
At code entry to silence
If fault exists, and after final arm
At disarm FIRST area (i.e. no longer
fully armed)
At code entry to disarm LAST area
At code entry to disarm LAST area
20 seconds after arm/disarm
procedure completed
After 3 seconds
When disarmed
At alarm, or when disarmed
At alarm, or when disarmed