5.4 Program Inputs?

By default, all inputs are set to 'unused'. Before programming, identify input type required:
No
Input Types
0
Unused
1
Fire
2
Gas
#
3
PA
#
4
Silent PA
5
Tamper
6
Instant
#$
7
Entry Delay1
$
8
Follow
11
Push To Arm
12
Switcher
13
24 Hour
PCX 46 Programming Reference
Operation
Factory default. Input is disabled.
Active at all times. Audible Response: Differentiated Internal sound.
Pulsed external sound.
Communicator: 'Fire' signal
Active at all times. Audible Response: Full external + Internal sound.
Communicator: 'Gas' signal
Active at all times. Audible Response: Differentiated Internal sound. Full
external sound.
Communicator: 'Personal Attack' and 'Input PA' signals
Active at all times. Audible Response: None
Communicator: 'Personal Attack' and 'Input PA' signals
When disarmed: Audible Response: Internal only.
Communicator: 'Tamper' signal.
When armed: Audible Response: Full external + Internal sound.
Communicator: 'Tamper' signal.
Active when armed: Audible Response: Full external + Internal sound.
Communicator: 'Burglary' signal
Active when armed: Initiates entry timer 1 when door open. If system not
disarmed before entry time expires then:
Audible Response: Full External + Internal sound.
Communicator: 'Burglary' signal
NOTE: See type 43 for Entry Delay2
Active when armed, except during entry time. (Acts as an instant input if
an Entry Delay input hasn't been activated beforehand)
Audible Response: Full external + Internal sound.
Communicator: 'Burglary' signals.
Active during exit time, to complete arming procedure. No audible or
communicator response. Panel will communicate a final armed event once
the Push to Arm button has been pressed.
NOTE: May be used to act as 'doorbell' by use of 'chime' input attribute.
Example: Wire the Door Bell button to the input. Enable "Push to Arm"
option from "EXIT MODES", add a "Push to Arm" input type to the input
and enable the "Chime" attribute for it.
Enter user code, the panel starts arming. Exit the building and close the
door. Press the Bell button. The system will arm. If pressing the Bell
button while the panel is in any other condition the Chime will sound.
Active at all times in armed and disarmed modes. No audible or
communication alarms will be created.
When activated it can trigger associated output for switching external
equipment. If the "Special Log" attribute is enabled for this input an SMS
message will be sent each time the input is activated.
Example:
This kind of input type can be used to control CCTV. The concept is that
when a switcher input type is activated, there is an output associated with
it following that input (the most used solution is the use of output type –
0035). The switcher input is connected to a detector located next to a
CCTV camera and the output is connected to a video recording /
transmitting equipment.
If the detector is activated in armed or disarmed mode then the recording
or transmission will start.
When armed: Audible Response: Full External + Internal sound;
Communicator: '24hr Alarm' signal.
When disarmed: Audible Response: Full External + Internal sound;
Communicator: '24hr Alarm' signal if enabled in "Alarm Responses" menu.