Pyronix PCX 46 Engineer Reference Manual page 20

Hide thumbs Also See for PCX 46:
Table of Contents

Advertisement

Choose Code Number
The user type can be Duress or Guard.
5.10.2 Duress Code
The Duress code can arm or disarm the system and if used a Duress communication event will be
sent. An output type is available to activate whenever this code is used (Duress type 008 - see page
32 Program Outputs).
User In Area
Choose the area the code is active in
User In Area
User Arm Options
[0] Disarm/Arm: The code will arm and disarm the areas selected in the previous option.
[1] Disarm Only: The code will only disarm the areas selected in the previous option.
[2] Arm Only: The code will only arm the areas selected in the previous option.
[3] None: No option programmed.
User In Area
User Arm Options
If user code is allocated to more than one area and is the Arm Area Choice option is set to NO, the
code will automatically arm all areas it has been allocated to in the same time. If the Arm Area Choice
has been set to YES then the user will be given the ability to choose which area to arm when the
arming procedure has been activated.
User In Area
User Arm Options
Write the name of the user for this code.
5.10.3 Guard Code
This code can disarm the system, but only after an alarm has been active for a minimum time
programmable in the timers. Use of this code will generate a normal user arm/disarm event. An
output type is available to signal whenever this code is used.
User In Area
Choose the area the code is active in
User In Area
User Arm Options
[0] Disarm/Arm: The code will arm and disarm the areas selected in the previous option.
[1] Disarm Only: The code will only disarm the areas selected in the previous option.
[2] Arm Only: The code will only arm the areas selected in the previous option.
[3] None: No option programmed.
User In Area
User Arm Options
If user code is allocated to more than one area and is the Arm Area Choice option is set to NO, the
code will automatically arm all areas it has been allocated to in the same time. If the Arm Area Choice
has been set to YES then the user will be given the ability to choose which area to arm when the
arming procedure has been activated.
User In Area
User Arm Options
Write the name of the user for this code.
NOTE: For both duress and guard codes is possible to program a tag too. In case tag is programmed
it has to be associated to a reader.
5.10.4 Change Master Manager Code
If a code or tag is already allocated, the display will show [******]. Press the  key to clear the
code and use the numeric keys to input the new code. This option allows the engineer to change the
Master Manager code shall this been lost or forgotten.
User In Area
Choose the area the code is active in
User In Area
User Arm Options
[0] Disarm/Arm: The code will arm and disarm the areas selected in the previous option.
[1] Disarm Only: The code will only disarm the areas selected in the previous option.
[2] Arm Only: The code will only arm the areas selected in the previous option.
[3] None: No option programmed.
PCX 46 Programming Reference
User Type
Arm Area Choice
Arm Area Choice
Arm Area Choice
Arm Area Choice
User Name
User Name
Page: 20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enforcer 32-we

Table of Contents