8.2.7 Errors When Arming
Fault
Please leave via
exit door
Exit Via...
Unable To Arm
Alarm during the
arming
Alarm during the
arming
procedure
PCX 46 Programming Reference
Description
If the exit mode is programmed
as Final Door, then you must
leave through that door to arm
the system.
If any follow detectors or door
contacts are open during the
arming procedure, this prompts
you to close them.
A fault condition exists on the
system. Details of the fault will
scroll on the display.
Fail to arm time has been
exceeded.
Instant inputs have been
activated.
Solution
Leave via the agreed exit route.
Close all inputs.
Correct the problem if it is an input which
is open, or call engineer.
Leave the premises within the fail to arm
time, increase the fail to arm time in
timers or disable this feature in system
options.
During the arming procedure do not
activate instant inputs.