  • Page 2: Table Of Contents

    Panel Mounting..................25 Chapter 3 AMI BIOS Setup ..................27 Overview ....................27 Main Menu ....................28 Advanced Menu..................29 Security Menu.................... 44 Boot Menu ....................45 Save & Exit Menu ..................46 Chapter 4 Driver Installation ..................47 KPC-1900 User’s Manual...
  • Page 3: Figures

    Figure 6 COM port ..................22 Figure 7 Turning on the system ..............23 Figure 8 VESA Mounting Hole Locations ........... 24 Figure 9 Panel Mount Cut-out hole and maximum panel thickness ... 25 Figure 10 Panel Mounting ................26 KPC-1900 User’s Manual...
  • Page 4: Tables

    Table 17 Advanced Menu – Network Stack ..........41 Table 18 Advanced Menu – H/W Monitor ........... 42 Table 19 Power Menu ................43 Table 20 Security Menu ................44 Table 21 Boot Menu ................... 45 Table 22 Save & Exit Menu ................ 46 KPC-1900 User’s Manual...
  • Page 5: Safety Instructions

    Turn off system power, turn off the power supply, and then disconnect the power cord from its source before removing the chassis cover. Turning off the system power switch does not remove power to components. KPC-1900 User’s Manual...
  • Page 6: When Working Inside A Computer

    ESD procedure to reduce the risk of damage to components. We strongly encourage you to follow proper ESD procedure, which can include wrist straps and smocks, when servicing equipment. You can also take the following steps to prevent damage from electrostatic KPC-1900 User’s Manual...
  • Page 7 Just before unwrapping the antistatic packaging, be sure you are at an ESD workstation or grounded. This will discharge any static electricity that may have built up in your body. KPC-1900 User’s Manual...
  • Page 8 Handle components and boards with care. Don’t touch the components or contacts on a board. Hold a board by its edges or by its metal mounting bracket.  Do not handle or store system boards near strong electrostatic, electromagnetic, magnetic, or radioactive fields. KPC-1900 User’s Manual...
  • Page 9: Preface

    (domestic environment) is likely to cause harmful interference, in which case the user will be required to correct the interference (take adequate measures) at their own expense. Changes or modifications not expressly approved by us could void the user's authority to operate the equipment. KPC-1900 User’s Manual...
  • Page 10: Maintaining Your Computer

    Refer to the “Specifications” section of this user’s guide for the operating and storage humidity specifications.  Altitude Operating a system at a high altitude (low pressure) reduces the efficiency of the cooling fans to cool the system. This can cause electrical problems related KPC-1900 User’s Manual...
  • Page 11 Surge protectors should be used with all UPS systems, and the UPS system should be Underwriters KPC-1900 User’s Manual...
  • Page 12 Preface Laboratories (UL) safety approved. KPC-1900 User’s Manual...
  • Page 13: Chapter 1 Introduction

    Chapter 1 Introduction  Overview Powered by 6th Generation Intel® Skylake S-Series Processors, KPC-1900 Panel PC has greatly improved graphics performance, power efficiency and wireless connectivity. In addition to 1x DVI-D, 2x DP, 4x USB 3.0, 2x USB 2.0, 3x...
  • Page 14: Product Specifications

    Power Adapter: AC to DC, 100 V ~ 240 V Firmware BIOS: AMI uEFI BIOS w/ 128 Mb SPI Flash Watchdog: Programmable WDT to generate system reset event H/W Monitor: Input & Core Voltages, CPU & System Temperatures KPC-1900 User’s Manual...
  • Page 15: Table 1 Product Specifications

    Operation Temp.: 0 °C ~ 50 °C / 32 °F ~ 122 °F Characteristics Storage Temp.: -20 °C ~ 70 °C / -4 °F ~ 158 °F Humidity: 0 % ~ 95 % Certification CE, FCC Class A, IP65 (front bezel) Table 1 Product Specifications KPC-1900 User’s Manual...
  • Page 16: System Tour

    The eight-pin RJ-45 LAN port supports a standard Ethernet cable for connection to a local network. Power Input The supplied power adapter converts AC power to DC for use with this phoenix connector or DC jack. Power supplied through this connector supplies power to KPC-1900 User’s Manual...
  • Page 17 MIC-IN (Pink) The microphone jack is designed to connect the microphone used for video conferencing, voice narrations, or simple audio recordings. Line-IN (Blue) The Line-in jack is designed to take input from a higher-powered sound source. KPC-1900 User’s Manual...
  • Page 18: Mechanical Dimensions

    Chapter 1 Mechanical Dimensions 448 x 373 x 72.5 mm (W x H x D) Figure 2 Mechanical Dimensions KPC-1900 User’s Manual...
  • Page 19: Chapter 2 Getting Started

    Chapter 2 Chapter 2 Getting Started  Setting up your PC  Connecting the monitor Connect the DP / DVI-D cable from your display to the DP / DVI-D port. DVI-D DVI-D Figure 3 DP / DVI-D KPC-1900 User’s Manual...
  • Page 20: Figure 4 Connect Usb Mouse & Keyboard

    Chapter 2  Connecting USB mouse & keyboard Your KPC-1900 does not come with a keyboard and mouse, but you can use any USB keyboard or mouse with your computer. Figure 4 Connect USB mouse & keyboard NOTE Using a third-party USB mouse or keyboard may require software drivers.
  • Page 21: Figure 5 Rj45 Connector

    Chapter 2  Connecting to a network device Connect one end of a network cable to the LAN port on the system rear panel and the other end to a hub or switch. Figure 5 RJ45 connector KPC-1900 User’s Manual...
  • Page 22: Figure 6 Com Port

    COM ports with the pin definitions. COM4 COM2 COM6 COM3 COM1 COM5 COM4 COM2 COM6 COM3 COM1 COM5 COM1~COM3 RS232/422/485 Port DB-9 Half Duplex Full Duplex RS232 RS422 RS485 RS485 DATA- DATA+ COM4~COM6 RS232 Port DB-9 RS232 Figure 6 COM port KPC-1900 User’s Manual...
  • Page 23: Figure 7 Turning On The System

    3. Connect the other end of the AC power cable to a corresponding AC power outlet. 4. Press the power switch on the I/O panel to turn on the system. Power Switch DC In (Phoenix Connector) Power Switch DC In (DC Jack) Figure 7 Turning on the system KPC-1900 User’s Manual...
  • Page 24: Vesa Mounting

    Use 4 screws with the appropriate length for your mounting bracket. Figure 8 VESA Mounting Hole Locations NOTE To fasten the metal shelf, your monitor must comply with VESA75 or VESA100 standard. The VESA mounting kit is optional. KPC-1900 User’s Manual...
  • Page 25: Panel Mounting

    The Panel PC can be panel mounted and comes with brackets and screws for this purpose. The required cutout for panel mounting and maximum panel thickness is shown below. Figure 9 Panel Mount Cut-out hole and maximum panel thickness KPC-1900 User’s Manual...
  • Page 26: Figure 10 Panel Mounting

    Insert a Panel Mount Secure brackets to Panel Opening Covers from the Bracket into each by tightening the screws chassis with Phillips Bracket Opening Screwdriver (3 on top edge, 3 on bottom edge) Figure 10 Panel Mounting KPC-1900 User’s Manual...
  • Page 27: Chapter 3 Ami Bios Setup

    It is possible for the CMOS battery to fail, which will cause data loss in the CMOS only. If this happens you will need to reconfigure your BIOS settings. KPC-1900 User’s Manual...
  • Page 28: Main Menu

    +/-: Change Opt. Frequency 2133 MHz F1: General Help F2: Previous Values F3: Optimized Defaults System date [Fri 11/25/2016] F4: Save & Reset System time [14:17:17] ESC: Exit Access Level Administrator Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. KPC-1900 User’s Manual...
  • Page 29: Advanced Menu

    F4: Save & Reset > Network Stack ESC: Exit > H/W Monitor Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. Onboard LAN 1 Controller Options: Disabled, Enabled Onboard LAN 2 Controller Options: Disabled, Enabled Audio Controller Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 30: Table 4 Advanced Menu - Display Configuration

    1024x768 18Bit 1CH, 1440x900 18Bit 2CH, 1600x900 18Bit 2CH, 1024x600 18Bit 1CH, 1366x768 18Bit 1CH, 1024x768 24Bit 1CH, 1280x1024 24Bit 2CH, 1366x768 24Bit 1CH, 1366x768 24Bit 2CH, 1440x900 24Bit 2CH, 1600x1200 24Bit 2CH, 1920x1080 24Bit 2CH, 1920x1200 24Bit 2CH KPC-1900 User’s Manual...
  • Page 31: Table 5 Advanced Menu - Super Io Configuration

    IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; Serial Port 1 Type Options: RS232, RS422, RS485  RS485 Duplex Mode Options: Half Duplex, Full Duplex  RS485 Auto Flow Control Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 32: Table 7 Advanced Menu - Super Io Configuration - Serial Port

    IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12 Serial Port 2 Type Options: RS232, RS422, RS485  RS485 Duplex Mode Options: Half Duplex, Full Duplex  RS485 Auto Flow Control Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 33: Table 8 Advanced Menu - Super Io Configuration - Serial Port

    IO=2F0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12 Serial Port 3 Type Options: RS232, RS422, RS485  RS485 Duplex Mode Options: Half Duplex, Full Duplex  RS485 Auto Flow Control Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 34: Table 9 Advanced Menu - Super Io Configuration - Serial Port

    IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2F0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12 KPC-1900 User’s Manual...
  • Page 35: Table 10 Advanced Menu - Super Io Configuration - Serial Port

    IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2F0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12 KPC-1900 User’s Manual...
  • Page 36: Table 11 Advanced Menu - Super Io Configuration - Serial Port

    IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2F0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=2E0h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12 KPC-1900 User’s Manual...
  • Page 37: Table 12 Advanced Menu - Cpu Chipset Configuration

    Options: Disabled, Enabled VT-d Options: Disabled, Enabled Active Processor Cores Options: All, 1, 2, 3 Limit CPUID Maximum Options: Disabled, Enabled Execute Disable Bit Options: Disabled, Enabled Intel Virtualization Technology Options: Disabled, Enabled Intel TXT(LT) Support Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 38: Table 13 Advanced Menu - Sata Configuration

    [Enabled] Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. SATA Controller(s) Options: Enabled, Disabled SATA Mode Selection Options: AHCI, RAID Serial STS Port 1/2/3/4 Port 1/2/3/4 Options: Disabled, Enabled mSATA Port 1/2 Port 1/2 Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 39: Table 14 Advanced Menu - Usb Configuration

    F4: Save & Reset USB Mass Storage Driver Support [Enabled] ESC: Exit Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. Legacy USB Support Options: Enabled, Disabled XHCI hand-off Options: Enabled, Disabled USB Mass Storage Driver Support Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 40: Table 15 Advanced Menu - Amt Configuration

    +/-: Change Opt. Un-Configure ME [Disabled] F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Reset ESC: Exit Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. Intel AMT Options: Disabled, Enabled Un-Configure ME Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 41: Table 16 Advanced Menu - Dio Configuration

    F2: Previous Values F3: Optimized Defaults F4: Save & Reset ESC: Exit Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. Network Stack Options: Disabled, Enabled  Ipv4 PXE Support Options: Disabled, Enabled  Ipv6 PXE Support Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 42: Table 18 Advanced Menu - H/W Monitor

    : +3.360 V F4: Save & Reset +VRTC : +3.216 V ESC: Exit +1.05V : +1.080 V Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. CPU Warning Temperature Options: Disabled, 80 C, 85 C, 90 C, 95 C KPC-1900 User’s Manual...
  • Page 43: Table 19 Power Menu

    Resume By LAN Device Options: Disabled, Enabled Resume By PCI-E Device Options: Disabled, Enabled Resume By Ring Device Options: Disabled, Enabled Resume By RTC Alarm Options: Disabled, Enabled Watchdog Timer Configuration WDT Function [Disabled] ■ Options: Disabled, Enabled KPC-1900 User’s Manual...
  • Page 44: Security Menu

    Minimum Length 3 Maximum length 20 Enter: Select +/-: Change Opt. Administrator Password F1: General Help User Password F2: Previous Values F3: Optimized Defaults F4: Save & Reset ESC: Exit Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. KPC-1900 User’s Manual...
  • Page 45: Boot Menu

    Version 2.17.1254. Copyright (C) 2016, American Megatrends, Inc. Full Screen LOGO Display Options: Disabled, Enabled Bootup NumLock State Options: On, Off CSM Support Options: Enabled, Disabled Boot Option Filter Options: UEFI and Legacy, Legacy only, UEFI only KPC-1900 User’s Manual...
  • Page 46: Save & Exit Menu

    Load Optimal Default values for all the setup values. This option allows you to load failsafe default values for each of the parameters on the Setup menus, which will provide the most stable performance settings. The F8 key can be used for this operation. KPC-1900 User’s Manual...