Pulse And Sdp Trip Rod Replacement - Graco Pulse Series Repair Manual

Metered dispense valve
Table of Contents

Advertisement

Pulse and SDP Trip Rod
Replacement
Pulse and SDP Models use Trip Rod Repair
Kit 25D903
1.
Follow Disassembly instructions, Steps
1 - 6, beginning on page 13.
2.
Remove the batteries and turn metered
dispense valve over.
3.
Remove 4 screws (21) and o-rings (20)
and carefully lift bezel (19) off housing
(12) (F
. 23).
IG
NOTE: The solenoid and power will still
be connected to the bezel via the power
connections as shown in F
the bezel can be completely separated
from the housing, these connections
must be detached.
F
. 23
IG
4.
Disconnect the red and white solenoid
connection (a) (F
3A5413F
. 23. Before
IG
19
12
20
21
. 24).
IG
5.
Disconnect the black and red power
connection (b) (F
NOTE: Be careful not to disturb the white
button board ribbon cable taped to the
bezel housing if reusing the bezel (19).
19
b
F
. 24
IG
6.
Loosen and remove solenoid (37) (F
25). The trip rod assembly (27) is located
below the solenoid.
F
. 25
IG
Service
. 24).
IG
a
37
27
.
IG
15