Bezel Replacement; Disassembly - Graco Pulse Series Repair Manual

Metered dispense valve
Table of Contents

Advertisement

Service
F
. 2
IG
5.
Replace cover (5) and screws (36).
Tighten screws hand tight. Do not
over-tighten screws(F
36
5
F
. 3
IG
8
. 3).
IG

Bezel Replacement

Pulse Meters use Bezel Replacement Kit
26C287
SDP Meters use Bezel Replacement Kit
26C403
SDM Meters use Bezel Replacement Kit
26C484
NOTE: The metered dispense valve does not
have to be taken out of service to replace the
bezel.

Disassembly

1.
Relieve pressure. See Pressure Relief
procedure, page 7.
2.
Remove batteries. See Battery
Replacement, page 7.
3.
Remove 4 screws (21) and o-rings (20)
and carefully lift bezel (19) off housing
(12) (F
. 4).
IG
NOTE: The solenoid (Pulse and SDP
Models only) and power will still be
connected to the bezel via the power
connections as shown in F
the bezel can be completely separated
from the housing, these connections
must be detached.
. 5. Before
IG
3A5413F