Sdm Trip Rod Replacement - Graco Pulse Series Repair Manual

Metered dispense valve
Table of Contents

Advertisement

14. Reinstall and firmly hand tighten the
solenoid (37) (F
F
. 29
IG
15. To complete the metered dispense
valve reassembly, see Reassembly
instructions page 20.

SDM Trip Rod Replacement

SDM Models use Trip Rod Repair Kit 26C394
1.
Follow Disassembly instructions, Steps
1 - 6, beginning on page 13.
2.
Remove the batteries and turn metered
dispense valve over.
3.
Remove 4 screws (21) and o-rings (20)
and carefully lift bezel (19) off housing
(12) (F
. 30).
IG
NOTE: The power will still be connected
to the bezel as shown in F
the bezel can be completely separated
from the housing, this connection must
be detached.
3A5413F
. 29).
IG
37
. 30. Before
IG
F
. 30
IG
4.
Disconnect the black and red power
connection (a) (F
NOTE: Be careful not to disturb the white
button board ribbon cable taped to the
bezel housing if reusing the bezel (19).
19
a
F
. 31
IG
Service
20
21
. 31).
IG
19
12
17

Hide quick links: