60-Litre - Initial Cold Water Operation
After carrying out the installation procedures
detailed in the previous chapter, run the initial
cold water operation as follows:
1. Lift the upper plastic cover off of the
dispenser by pulling it up.
2. If not done already, fill the ice tank with
clean water paying special attention not
to wet any of the electrical components.
3. Fill the ice tank to the arrow that indicates
the maximum level (see Fig 1). After filling
the tank do not move the dispenser as
doing so could cause water to spill from
the tank. NOTE: if this device is operated
without water in the ice tank it will cause
serious damage to the machine.
4. Dry any drops or splashes caused by
filling the ice tank.
5. Pull the ring of the safety valve on the
carbonator, releasing gas for at least 2/3
seconds (see Fig 2).
6. Open the water shut off valve on the
supply line.
Fig 1
Install & Operation Manual
7. Place a container with a capacity of at
least 5 litres under the dispensing taps.
8. Dispense at least 3/4 litre of ambient still
water, and at least 3/4 litre of chilled
water.
9. Position the thermostat switch to number 7,
and wait for 2 - 3 minutes.
10. Position the 5 litre container under the
sparkling water tap and dispense until
only gas comes out.
11. Replace the upper plastic cover and wait
for 90 - 120 minutes before dispensing
water again so ice may form in the tank.
12. Once started the device must be left
operating permanently. If the power supply
is interrupted for more than 2 - 3 hours it
could cause faults within the ice tank and
consequently freeze the water coil. NOTE:
If a similar anomaly occurs follow ice bank
defrosting procedure (see page 26).
Fig 2
18
On/Off Switch
(For Chilled & Sparkling)
Cold Thermostat
Turn clockwise to decrease water
temperature
GB