Extended power range and bias tees upgrade kit

Advertisement

• W120 (N5247-20064) A47 port 3 receiver attenuator to A28 mixer brick (C)
• W54 (reuse) (N5247-20062) REF 3 RCVR R3 IN to A28 mixer brick (R3)
* As shown in
Figure
W54 (N5247-20062).
Figure 13
Location of Cable Ties to Secure W120 (N5247-20064) and W54 (N5247-20062)
• W107 (N5247-20010) Port 3 CPLR THRU to A43 port 3 bias tee
• W34 (reuse) (N5247-20082) A33 port 1 coupler to front-panel port 1 CPLR ARM
• W117 (N5247-20013) Front-panel port 1 RCVR A IN to A46 port 1 receiver attenuator
• W102 (N5247-20014) A38 port 1 source attenuator to front-panel port 1 SOURCE OUT
• W108 (N5247-20028) A43 port 3 bias tee to A34 port 3 coupler
Installation Note N5247-90103
13, install 2 cable ties, part number 1400-0249, to secure W120 (N5247-20064) and
27