Recommended Twisted Pair Cables - Guntermann & Drunck ControlCenter-Digital-288 Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

Recommended twisted pair cables

Recommended twisted pair cables
The signals between the IO card
modules are transmitted using category 5e (or better) twisted pair cables.
NOTE:
It is permitted to connect several segments of a cable connection with patch
panels and connection ports. It is, however, not permitted to connect active com-
ponents such as network switches, hubs or repeaters.
The data transmission is reliable over a distance of at least 80 metres using a regular
standard twisted pair cable (category 5e or better).
The distance that can actually be bridged depends on the quality of the applied
cable. High-quality S-STP cables with an AWG22 wire gauge coding can bridge a
distance of up to 140 metres.
Patch cables with an AWG26 wire gauge coding can only bridge a maximum of 80
metres.
In order to ensure reliable operation even in environments with interferences, use
installation cables with at least AWG24 coding for lengths over 80 metres:
Wire gauge
AWG22
AWG24
AWG26/27
NOTE:
The lengths mentioned in the table above must be interpreted as the sum of
all segments between the devices.
The following cables achieved the best results during test operation:
Up to 80 meters:
Up to 100 meters:
Up to 140 meters:
16 · G&D ControlCenter-Digital-288
CCD-IO16-Card-CAT
Cable type
Installation
Installation
Patch cable
Dätwyler uninet® 7702 flex
Patch cable
Dätwyler uninet® 5502 AWG24 S-STP
Installation cable with sockets
Kerpen MegaLine® G12-150 S/F AWG22
Installation cable with sockets
Dätwyler uninet® 7702 AWG 22
Installation cable with sockets
and the connected target and user
Category
5e, 6 or 7
5e, 6 or 7
5e, 6 or 7
Recommendation
Up to 140 m
Up to 120 m
Up to 80 m