Operation
4.1 General notes
Please read section 3 Indicators and Control Ele-
ments thoroughly before operating the machine if
you are not yet fully familiar with the indicators and
control elements of the machine.
All indicators and control elements are described
in detail in this chapter.
36
4.2 Tests before taking into op-
eration
The following inspections must be carried out be-
fore each working day or before a longer working
period.
Danger
!
Danger of accident!
Please observe strictly the safety regulations
in chapter 2 of this instruction manual!
Park the machine on ground as level as possi-
l
ble.
Check:
fuel tank and fuel lines for leaks
l
screw joints for tight fit
l
function of steering
l
machine for cleanliness, damage
l
presence of the appropriate operating and
l
maintenance instructions,
check whether the machine has been properly
l
serviced.
i
Note
For a description of the following tasks refer to the
chapter "maintenance every 10 operating hours".
Engine oil level
l
i
Note
In hydraulic systems filled with Panolin HLP Synth.
32 always use the same oil to top up. With other
ester based oils consult the lubrication oil service
of the respective oil manufacturer.
Check the hydraulic oil level, top up if neces-
l
sary.
Hydraulic oil filter contamination indicator
l
Check the coolant level, top up if necessary.
l
Danger
!
Fire hazard!
Do not refuel in closed rooms.
Check the fuel level, top up if necessary.
l
BOMAG
BW 80 AD-2 Fam.