Cleaning The Water Sprinkler System - Bomag BW 80 AD-2 Operating Instructions, Maintenance Instructions

Tandem vibratory/combination roller, side free tandem roller
Table of Contents

Advertisement

Every 250 operating hours
5.23 Cleaning the water sprinkler
system
i
Note
In the event of frost observe the special mainte-
nance notes 'water sprinkler system, maintenance
in the event of frost'.
Drain the water tank.
l
Fig. 110
Open the rear flap 1 (Fig. 110).
l
Unscrew the spigot nut (2).
l
Unscrew the water filter (3) and clean it.
l
Flush the water tank thoroughly.
l
Screw the water filter back in, tighten the spig-
l
ot nut and close the flap.
Fig. 111
Pull the caps 3 (Fig. 111) off both sprinkler
l
tubes.
76
Loosen the hose clamps (2) and pull the hoses
l
of the sprinkler tubes.
Pull the sprinkler tubes (3) out and flush them
l
thoroughly.
Assemble the sprinkler tubes and fill the water
l
tank.
Environment
Dispose of emulsion fluid environmentally.
Drain the emulsion tank.
l
Fig. 112
Unscrew the fitting.
l
Take the emulsion filter (Fig. 112) out and
l
clean it.
Thoroughly rinse the emulsion tank.
l
Reinsert the emulsion filter.
l
Turn the fitting back on.
l