Every 250 operating hours
Fig. 104
Set the fuel shut-off lever (Fig. 104) to vertical
l
position.
Fig. 105
Open the bleeding screw (Fig. 105) on the in-
l
jection pump for a few turns.
Crank the engine with the starter until fuel runs
l
out without air bubbles.
Retighten the bleeding screw.
l
74
5.22 Cleaning the cooling fins on
radiator and hydraulic oil
cooler
Danger
!
Danger of injury!
Cleaning work should only be carried out with
the engine stopped and cooled down.
Caution
!
Take care to avoid deformation of the radiator
cooling fins.
i
Note
Dirt on blower wings and oil cooler reduces the
cooling efficiency. Dampness caused by oil and
fuel on these surfaces support the accumulation of
dirt in these areas. You should therefore eliminate
any oil or fuel leaks in these areas immediately
and clean the cooling surfaces after.
Coolant radiator
Fig. 106
Remove the blower grid.
l
i
Note
Start to blow out from the air discharge side.
Blow the radiator (Fig. 106) out with com-
l
pressed air from the air discharge side.
BOMAG
BW 80 AD-2 Fam.