Hints, Tips And Help - roco MultiMAUS Manual

H0, h0e, tt.
Hide thumbs Also See for MultiMAUS:
Table of Contents

Advertisement

Available languages

Available languages

 Z21 and Booster
They supply the model railway system with the necessary voltage and conduct the digital control signals
from the multiMAUS to the locomotives, turnouts and other digital accessories.
The Z21 manages all control commands and other information centrally (therefore, this also includes the
Z21 digital control centre). The Z21 also generates the digital track system (and much more).
 X-BUS
The X-BUS is the connection between the digital components (multiMAUS, booster, interface etc.) and not
only supplies voltage but is also responsible for data exchange.
The master mouse always has a fixed address, other devices search automatically for free addresses so
that you normally do not need to make any changes.

Hints, Tips and Help

Library or locomotive address mode:
Selected locomotive does not react
The Turnout reacts incorrectly or the turnout
setting does not match display
POM mode: Programming is confirmed, but
the decoder does not react to an altered
value
The multiMAUS cannot be reset (3.5., page
55)
Scrolling in locomotive address mode is slow
or not possible at all
60
60
8051281925.indd 60
▪ Does the locomotive address in the library match the
address in the locomotive decoder?
▪ Has an emergency stop or selective emergency stop
been triggered?
▪ Select an address in locomotive address mode.
▪ Turn the plug on the turnout drive.
▪ Decoder needs to be reset: Switch the track voltage
off and back on again using the "STOP" key (emer-
gency stop). See the operating manual for the de-
coder.
▪ In this case, it helps to pull the plug and press the
shift key together with the "MENU" key when plug-
ging the cable back in.
▪ The multiMAUS is reset completely to the factory
settings. Since this deletes the locomotive library,
you should make sure you are certain you wish to
take this step.
▪ There is a problem with the X-BUS. Switch the system
off and back on again. Check whether menu item
3.3.2. is set to "automatic". It is possible that two
devices have the same X-BUS address.
10.05.2016 12:52:19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents