2. Technical Data
a. Gas Specifications
Manifold
Pressure*
In-Line Pressure
Shaded areas are stated in metric equivalents
* Measured at the gas valve pressure tap when the gas valve is on.
b. Gas Connections:
Inlet connection --- 1-1/2" F.P.T.
Inlet supply size --- 1-1/2" N.P.T. (minimum)
Btu/hr input -------- 550,000 (138,600 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
kcal/hr
Btu/hour
Rating
Rating
138,600
550,000
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ............................ #2 = 0.2210" (5.6134 mm).
Liquid Propane Gas ................ #29 = 0.1360" (3.4544 mm).
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C.
TYPE OF GAS
Natural
Qty.
D.M.S.*
Part No.
4
#2
140839
8.7 mb
10.5 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
Liquid Propane
Qty.
D.M.S.*
4
#29
26
LIQUID PROPANE
26.1 mb
27.4 mb
Liquid
Propane
Conversion Kit
Part Number
Part No.
140820
880978