(Optional) Installing Network Port Lightning Protectors - H3C WX3500H Series Installation Manual

Hide thumbs Also See for WX3500H Series:
Table of Contents

Advertisement

Grounding the device with a grounding conductor buried in the earth—If earth is
available at the installation site, hammer a 0.5 m (1.64 ft) or longer angle iron or steel tube
into the earth to serve as a grounding conductor. Weld the yellow-green grounding cable to
the angel iron or steel tube and treat the joint for corrosion protection.
Figure 11 Grounding the device by burying the grounding conductor into the earth
(WX3540H)
(Optional) Installing network port lightning
protectors
IMPORTANT:
• Before installing a network port lightning protector, read the instructions in the document that
comes with the protector.
• Network port lightning protectors are available only for 10M/100M/1000M RJ-45 Ethernet copper
ports.
• If multiple network ports have network cables routed outdoors, install a network port lightning
protector for each network port.
If part of the network cable for a network port is routed outdoors, install a network port lightning
protector for the port to protect against damages caused by lightning strikes.
No network port lightning protectors are provided with the device. Purchase them yourself as
required.
To install a network port lightning protector for a network port:
Use a double-faced adhesive tape to stick the network port lightning protector onto the device
1.
chassis, and make sure it is as close to the grounding screw of the device as possible.
Cut the ground wire of the protector to a length (as short as possible) as required by the
2.
distance between the protector and the grounding screw of the device. Attach the ground wire
securely to the grounding screw of the device.
Make sure the grounding screw of the device is reliably grounded.
Use a multimeter to verify that the ground wire of the protector makes good contact with the
3.
grounding screw of the chassis.
Insert the outdoor network cable into the protector's Surge end marked IN, and insert the cable
4.
from the network port into the Protect end marked OUT.
Examine the port LED to verify that the port is operating correctly.
5.
14