Installation Tools; Pre-Installation Checklist - H3C WX3500H Series Installation Manual

Hide thumbs Also See for WX3500H Series:
Table of Contents

Advertisement

Accessory
Front mounting bracket

Installation tools

No installation tools are provided with the device. Prepare installation tools as required.
Figure 3 Installation tools
Flathead screwdriver
Diagonal pliers

Pre-installation checklist

Table 5 Pre-installation checklist
Item
Installation
site
WX3508H
Phillips screwdriver
Mark
Requirements
Ventilation
Temperature
0°C to 45°C (32°F to 113°F)
Humidity
5% RH to 95% RH (noncondensing)
Cleanliness
ESD prevention
WX3510H
× 2
Needle-nose pliers
ESD wrist strap
There is a minimum clearance of 100 mm (3.94 in))
around the inlet and outlet vents for heat dissipation
of the device chassis.
A good ventilation system is available at the
installation site.
Dust concentration ≤ 3 × 10
No dust on desk within three days
The equipment and rack or workbench are reliably
grounded.
The equipment room is dust-proof.
The humidity and temperature are at acceptable
levels.
An ESD wrist strap is available.
6
WX3520H
×
× 2
2
Wire-stripping pliers
4
3
particles/m
WX3540H
×
2
Result