Flushing

Flushing
There are times when you only want to flush the fluid
manifold, such as:
breaks in spraying
overnight shutdown
end of potlife
In this manual, that procedure is referred to as Fluid
Manifold Flushing. You can flush the fluid manifold by
connecting a solvent pump to the fluid manifold.
Other times, you need to flush the entire system:
first time material is loaded into equipment*
color change
servicing
shutting down equipment for more than 3-1/2 hours
(depends on material)
putting equipment into storage
*
Some Full System Flushing steps are not necessary for
initial flushing, as no material has been loaded into the sys-
tem yet.
To flush the entire system, you first follow the Fluid
Manifold Flushing procedure, at right, then the Full
System Flushing procedure, page 18.
WARNING
Read warnings, page 5.
Use the lowest possible pressure when flush-
ing to avoid splashing.
Before color change or shutdown for storage,
flush at a higher flow rate and for a longer
time.
A circulation setting is available. Consult your
distributor. Refer to page 27.
16

Fluid Manifold Flushing

Using Solvent Pump
1.
Follow Pressure Relief Procedure, page 14.
Engage trigger lock. Remove spray tip.
2.
Ensure that shutoff valves G
Connect solvent pump line to solvent purge valve J
B
and J
. Turn on solvent pump and open solvent
A
purge valve J
.
A
J
3.
Adjust solvent pump regulator to desired pressure;
use lowest pressure possible.
TI1948A
TI1948A
A
B
and G
are open.
A
B
G
B
J