AIR DRIVEN, 5 GAL. (19 LITER) SIZE
Agitators
For mixing and maintaining suspension of industrial coatings.
For professional use only.
100 psi (0.7 MPa, 7 bar) Maximum Working Pressure
Model 226086, Series F
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.

Table of Contents

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
4
7
7
8
9
10
10
2575
306670K
01174b
II 1/2 G T6
ITS03ATEX11251
ENG

Advertisement

loading

Summary of Contents for Graco 226086

  • Page 1: Table Of Contents

    306670K For mixing and maintaining suspension of industrial coatings. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum Working Pressure Model 226086, Series F Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
  • Page 2: Warnings

    D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call Graco Technical Assis- tance at 1--800--543--0339.
  • Page 3 WARNING WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 6. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately.
  • Page 4: Installation

    Installation Preparing the Agitator for Use WARNING 1. Set the air motor (B) in the opening in the cover (1) FIRE AND EXPLOSION HAZARD as shown in Fig. 1. Secure with the two setscrews Always maintain a minimum of 1 in. (5), using the allen wrench (4).
  • Page 5 Installation 01176b 1/8 npt(f) Air Inlet 01175b Fig. 1 306670...
  • Page 6 Installation Grounding System Accessories Proper grounding is an essential part of maintaining a On the air line, install an air line filter to remove harm- safe system. ful dirt and moisture from the compressed air supply. Order Part No. 106148 filter, which is 3/8 npt(f) or To reduce the risk of static sparking, all electrically 106149 filter, which is 1/2 npt(f).
  • Page 7: Operation

    D If the unit requires more than installation of a ser- gases. vice kit, it is usually quickest and easiest to send the unit to the Graco distributor for repair or re- D Do not use kerosene or other flammable sol- placement.
  • Page 8: Parts

    Parts Model 226086, Series F REF 2 Ref. Part No. Description Qty. 205342 COVER, pail REF 2 (includes item 1a) 110312 . PLUG, button 224571 AGITATOR ASSEMBLY See Manual 306565, Rev C or later, to order parts 100220 THUMBSCREW; 5/16--18 x 1”...
  • Page 9: Technical Data

    Technical Data Maximum Working Pressure ..100 psi (7 bar) *Noise Level at 100 psi (7 bar) at normal load Motor power rating ....1/4 HP (187 W) at 800 rpm: Pressure .
  • Page 10: Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.