Shutdown Instructions - ADC AD-115ES Installation Manual

Adc compact dryer installation manual
Hide thumbs Also See for AD-115ES:
Table of Contents

Advertisement

REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left
rear area of the dryer.
Both the Dwell (Stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches
located on the electronic timer (as noted in the illustration below).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
Time in Seconds*
DWELL (STOP) TIME
Adjustment Position Number
Time in Seconds*
* Values shown are +/- 1-second.
M. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS – discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve.
2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.
b. STEAM MODELS – discontinue the steam supply.
1) SHUT OFF external (location furnished) shutoff valve.
2) SHUT OFF internal steam valves in the supply lines and the return lines.
113202 - 10
1
2
3
4
5
30
60
90
120
150
1
2
3
4
5
5
6.3
7.6
8.9
10.2
www.amdry.com