Reversing, 3ø Motor (Electric)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY .
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) type ONLY . For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
PHASE
VOLTAGE
208
230
240
380
400
416
460
480
575
208
230
240
380
400
416
460
480
575
*
AWG Stranded Wire Type; size wire as per National Electrical Code or local codes. (Motor lead wire is recommended.)
** 3-Wire is available.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the
case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
IMPORTANT: 380, 400, and 416 volt dryers are built 4-wire only. Customer must contact the
factory to special order 3-wire systems.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
113202 - 10
APPROX.
WIRE
AMP DRAW
SERVICE
60 Hz
3
181
3
3
159
4**
4**
4**
3
83
3
80
3
66
3
214
3
3
188
4**
4**
4**
3
98
3
94
3
78
www.amdry.com
MINIMUM
WIRE SIZE
50 Hz
60 kW
*
167
*
*
100
*
95
*
92
*
*
*
*
72 kW
*
197
*
*
118
*
112
*
109
*
*
*
*
FUSING
CIRCUIT
Dual Element
BREAKER
Time Delay
250
250
200
200
200
200
125
125
125
125
125
125
125
125
100
100
100
100
300
300
250
250
250
250
150
150
150
150
150
150
125
125
125
125
100
100