AERMEC NXW Usage Manual page 65

Electronic adjustment for water-cooled heat pumps
Hide thumbs Also See for NXW:
Table of Contents

Advertisement

Available languages

Available languages

47
VS1 - liquid solenoid valve 1 circ.2
54
Circuit 1 total recovery bypass valve
55
Circuit 2 total recovery bypass valve
56
Circuit 1 spillage from recovery
57
Circuit 1 spillage from condenser
58
Circuit 2 spillage from recovery
59
Circuit 2 spillage from condenser
100
Alarm summary
101
ALP40 - evaporator pump 1 flow switch alarm
102
AL46 - condenser pump 1 flow switch alarm
103
ALP42 - Evaporator pump 1 circuit breaker alarm
104
ALP43 - Evaporator pump 2 circuit breaker alarm
105
AL63 - Condenser pump 1 circuit breaker alarm
106
AL64 - Condenser pump 2 circuit breaker alarm
109
ALC30 - Compressor 1 circ. 1 circuit breaker alarm
110
ALC30 - Compressor 2 circ. 1 circuit breaker alarm
111
ALC30 - Compressor 3 circ. 1 circuit breaker alarm
112
ALC30 - Compressor 1 circ. 2 circuit breaker alarm
113
ALC30 - Compressor 2 circ. 2 circuit breaker alarm
114
ALC30 - Compressor 3 circ. 2 circuit breaker alarm
115
AL65 - Fan 1 circuit breaker alarm
116
AL66 - Fan 2 circuit breaker alarm
117
ALU50 - Evaporator antifreeze alarm
118
Not used
119
ALB34 - Circ. 1 low pressure switch alarm
120
ALB34 - Circ. 2 low pressure switch alarm
121
ALB35 - Circ. 1 low pressure alarm
122
ALB35 - Circ. 2 low pressure alarm
123
AL75 - Circ. 1 serious low pressure alarm
124
AL76 - Circ. 2 serious low pressure alarm
125
ALB36 - Circ. 1 high pressure switch alarm
126
ALB36 - Circ. 2 high pressure switch alarm
127
ALB37 - Circ. 1 high pressure alarm
128
ALB37 - Circ. 2 high pressure alarm
129
ALR03 Phase monitor alarm
130
ALA15 - Evap. 1 outlet probe faulty alarm
131
ALA13 - Evap. 1 inlet probe faulty alarm
132
ALA20 - Condenser 1 outlet probe faulty alarm
133
ALA14 - Condenser 1 inlet probe faulty alarm
134
AL91- Recovery 1 outlet probe faulty alarm
135
AL90- Recovery 1 inlet probe faulty alarm
136
ALA05 - Circ. 1 high pressure probe faulty alarm
137
ALA09 - Circ. 1 low pressure probe faulty alarm
138
ALA06 - Circ. 2 high pressure probe faulty alarm
139
ALA10 - Circ. 2 low pressure probe faulty alarm
140
ALA25 - External temperature probe faulty alarm
147
ALP41 - evaporator pump 2 flow switch alarm
148
ALP47 - condenser pump 2 flow switch alarm
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
---
R
65