11.1.3 DI Function and Operation Setup Screen-3
▶ Able to set operation for each DI Signal.
▶ DI Operation Type
☞ Error Stop : Display DI Error Screen and stop operation when DI error occurs.
☞ Time Stop : Display DI Error Screen and stop operation after preset delay time when DI error occurs.
☞ Error Run : Display DI Error Screen and maintain current run operation when DI error occurs.
☞ Run : DI Do not Display DI Error Screen and maintain current run operation when DI error occurs.
- Generate Status Display Lamp and Error Signal at [Run Screen-2].
Table 11-4 DI Function and Operation Setup Screen-3 Parameter
Parameter
DI #n Run after Signal Sense
DI #n Signal Delay Time
* #n = 1 ~ 16
2nd Edition of TEMP2000_Series IM : July. 16. 2010
[Figure 11-3] DI Function and Operation Setup Screen-3
[Figure 11-4] DI Function and Operation Setup Screen-3
Error Stop, Time Stop, Error Run, Run
0.00 ~ 99.59 (MIN.SEC)
Range
Unit
Default
ABS
Error Stop
ABS
00.00
Page 74 / 87