Safety Notes; Installation Instructions; Flow Diagram - Hans Grohe Talis S2 32047000 Instructions For Use/Assembly Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
6

Safety Notes

6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart®
(flow limiter) located behind the aerator can be
removed.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
Assembly see page 33
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 33. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 34)

Flow diagram

(see page 35)
with EcoSmart®
without EcoSmart®
Spare parts (see page 36)
Operation (see page 35)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning (see enclosed brochure.
Remedy
- Clean aerator, replace as
necessary
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Talis care 32037000

Table of Contents