Safety Notes

� Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning pur-
poses.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The product is not designed to be used with steam baths!
Thermostatic mixer in conjunction with combination boilers
• If fitting a hand shower remove the water limiter from the shower.
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections R 1/2:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
Shower or spout dripping
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
150 mm
cold right - hot left
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Hot and cold supplies are reversed
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
Assembly (see page 31)
Do not use silicone containing acetic acid!
Safety Function (see page 35)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance (see page 37)
• The check valves must be checked regularly according to DIN
EN 1717 in accordance with national or regional regulations (at
least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Operation (see page 36)
Dimensions (see page 34)
Flow diagram (see page 34)
Shower outlet
Outlet for additional consumer (free flow)
Spare parts (see page 39)
Cleaning (see page 40)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- change connections
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Exchange shut-off unit