Thermal Design - Seco Qseven CQ7-A42 User Manual

Carrier board for rel. 2.0, compliant modules on 3.5" form factor
Table of Contents

Advertisement

4.1 Thermal Design

A parameter that has to be kept in very high consideration is the thermal design of the system.
Highly integrated modules, like Qseven
the counterpart, the miniaturising of IC's and the rise of operative frequencies of processors lead to the generation of a big amount of heat, that must be dissipated
to prevent system hang-off or faults.
®
Qseven
specifications take into account the use of a heatspreader, which will act only as thermal coupling device between the Qseven
dissipating surface/cooler. The heatspreader also needs to be thermally coupled to all the heat generating surfaces using a thermal gap pad, which will optimise
the heat exchange between the module and the heatspreader.
The heatspreader is not intended to be a cooling system by itself, but only as means for transferring heat to another surface/cooler, like heatsinks, fans, heat pipes
and so on.
Conversely, heatsinks in some situation can represent the cooling solution. Until the modules are used on a development Carrier board, on free air, just for software
development and system tuning, then a finned heatsink could be sufficient for modules' cooling. Anyhow, please remember that all depends also on the workload
of the processor. Heavy computational tasks will generate much heat.
Indeed, when using CQ7-A42 carrier board with any Qseven
scenario of utilisation.
Therefore, it is always necessary that the customer study and develop accurately the cooling solution for his system, by evaluating processor's workload, utilisation
scenarios, the enclosures of the system, the air flow and so on. This is particularly needed for industrial grade modules.
®
SECO can provide Qseven
modules' specific heatspreaders and heatsinks, but please remember that their use must be evaluated accurately inside the final
system (electronics + mechanics), and that they should be used only as a part of a more comprehensive ad-hoc cooling solutions, which also keeps the surface
temperature of all carrier board's components in the temperature range specified for the specific carrier board configuration (industrial or commercial grade).
CQ7-A42
CQ7-A42 - Rev. First Edition: 1.0 - Last Edition: 2.0 - Author: S.B. - Reviewed by G.G. Copyright © 2016 SECO S.r.l.
®
modules, offer to the user very good performances in minimal spaces, therefore allowing the systems' minimisation. On
®
module, it is necessary to consider carefully the global heat generated by the system, and the
®
module and an external