WARNING! only use heater in well ventilated areas. ensure continuous ventilation is provided to the heater operating area via
windows and doors etc. if people are not required to be present in the heated area, the volume of air to be heated (mtr³)/
heat output (kW) ratio must be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. if
people are required to be present in the heated area, the volume of air to be heated (mtr³)/heat output (kW) ratio must be
at least 30:1. Ventilation must be to the outside of the premises in which the heater is to be operated. the total open area (mtr²) must be
at least 0.003 times the total heat output (kW). the volume concentration of oxygen (o²) in the heated room, must always remain above
17%.
‰ ‰ WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
‰ ‰ DO NOT switch the heater off by disconnecting it from the mains. ALWAyS set the switch on the burner to the 'off' position and
‰ 8
allow the cooling cycle to finish, before disconnecting from the mains.‰‰
DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any walls or
8
objects.
‰ ‰ DO NOT use the heater in closed rooms, living areas, basements or below ground level.
‰ 8
‰ ‰ DO NOT allow untrained persons to operate the heater and DO NOT operate the heater without the safety guard.
‰ 8
‰ ‰ DO NOT move or handle the heater when hot, without wearing protective gloves. never move the heater whilst it is operating.
‰ 8
‰ ‰ DO NOT leave the heater unattended for prolonged periods of time when in use. switch the heater off and unplug from the
‰ 8
mains before leaving work area.
‰ ‰ DO NOT fill the fuel tank whilst the heater is running or still hot. DO NOT overfill the fuel container. Wipe up any spilt fuel
‰ 8
immediately.
‰ ‰ DO NOT obstruct the air inlet (rear) and air outlet (front) of the heater and DO NOT use duct work in front or at the rear of the
‰ 8
heater.
‰ ‰ DO NOT allow children or animals near the heater when in use, or whilst still hot.
‰ 8
‰ ‰ WARNING! RISK OF ELECTRIC SHOCK. DO NOT expose the heater to water spray, rain, dripping water or wind.
‰ ‰ DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
‰ 8
‰ ‰ DO NOT touch the heater outlet or cone when in use, or for a period of time after it's switched off, as these are VERy hot and will
‰ 8
take time to cool down.
‰ ‰ DO NOT use an external fuel tank. Only use the tank that is fitted to the heater, and only fill it when the heater has cooled down.
‰ 8
‰ ‰ ensure that the heater is correctly turned off.
9
When not in use for an extended period, store in a safe, dry area, out of reach of children.
9
Important: this appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. children should be supervised to ensure that they do not play with the appliance.
2. INTRODUCTION
infrared heater suitable for well ventilated indoor applications. clean burning unit operates on paraffin, kerosene or diesel. unit produces an
impressive 125,000 Btu/hr on highest setting. 53ltr tank allows a max. of 20 hrs running time dependant on setting, making this unit extremely
economical. complies with rigorous standards and is fitted with a safety cut-out.

3. SPECIFICATION

Model
Heat output
rating
fuel
running time Per filling (max)
fuel tank capacity
Heated Area
Voltage/Hz
rated Amps
net Weight
radiant
visor screws
© Jack sealey limited
IR37.V4
28 / 37 kW
95,000 / 125,000 Btu/hr
Paraffin / Kerosene / Diesel
20 hrs
53 litres
25000ft³ / 708m³
230 ~ 50Hz
3
33kg
Fig.1A
Original Language Version
This heater is not suitable for use with
‰ WARNING!‰
Bio-Diesel; use of Bio-Diesel will damage
the filter and seals.
Damage caused by use of Bio-Diesel will
not be covered by warranty.
Green (Power on)
low
setting
Power
off.
3 Position switch on
control Panel
tips on ignition:-
the photocell is sensitive to sunlight, ignite in the shade.
listen for fan followed by pump, after switch position "
Priming essential when new, see 5.3.4.
Observe the fuel level in the filter bowl.
clean fuel requires clean reservoir and clean transfer cans.
Flashing Red (Misfire)
High
setting
"
ir37.V4 | issue 3 (i) - 11/08/17