Repair Information

If you need to replace the MS-FEU1611-0U controller, contact the Johnson Controls Repair Center in Louisville,
Kentucky, at 1-502-671-7312. This model has special restrictions because it is UL 864 10th Edition UUKL/ORD-
C100-13 UUKLC listed for smoke control.
Accessories
Use
Table 5
to order accessories.
Table 5: FEU16 Accessories Ordering Information
Product Code Number
PAN-PWRSP-U
MS-FUSE01-1

Technical Specifications

FEU1610 Controller
Product Code Numbers
Supply Voltage
Power Consumption
Ambient Conditions
Terminations
Controller Addressing
Communications Bus
Mounting
Housing
Analog Input/Analog
Output Resolution and
Accuracy
Dimensions
(Height x Width x Depth)
Weight
Compliance
The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these
specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or
misuse of its products.
Description
Transformer, 120/24 VAC, 96 VA, with circuit breaker and 120 VAC outlet, approved for Smoke
Control
Replacement fuse (Bulk Pack of 10)
MS-FEU1610-0U Field Equipment Controller
20 - 30 VAC at 50 or 60 Hz, Class 2
10 VA typical, 14 VA maximum, plus all BO and CO loads
Operating: 0 to 50°C (32 to 122°F); 10 to 90% RH noncondensing
Storage: -40 to 70°C (-40 to 158°F); 10 to 90% RH noncondensing
Screw Terminals and Screw Terminal Pluggable Blocks
DIP switch set (4-127). Addresses 0-3, 128-255 are reserved.
BACnet® MS/TP; 3-wire FC Bus between the NAE and other devices. 4-wire SA Bus
between network sensors and other devices.
On flat surface with screws on three mounting clips or a single 35 mm DIN rail
Plastic housing
Plastic material: ABS and polycarbonate UL94 5VB
Analog Input Points: 15-bit resolution
Analog Output Points: 16-bit resolution, +200 mV accuracy
144 x 127 x 58 mm (5.68 x 5 x 2.25 in.)
Minimum space for mounting: 174 x 350 x 110 mm (6.8 x 13.8 x 4.3 in.)
0.5 kg (1.10 lb)
United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management
Equipment; FCC Compliant to CFR47, Part 15, Subpart B, Class A
UL Listed, File S4977, UL 864 UUKL/UUKLC 10th Edition Listed, Smoke Control Units and
Accessories for Fire Alarm Systems Equipment
Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal
Equipment; Industry Canada Compliant, ICES-003
UL Listed, File S4977, UL 864 UUKL/ORD-C100-13 10th Edition Listed, Smoke Control Units
and Accessories for Fire Alarm Systems
Europe: CE Mark, EMC Directive, in accordance with EN 61000-6-3 and EN 61000-6-2, and
the Low Voltage Directive in accordance with EN 60730.
Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant.
BACnet International: BACnet Testing Laboratories™ (BTL) 135-2004 Listed BACnet
Application Specific Controller (B-ASC)
FEU16x0 Field Equipment Controller Installation Instructions
13