Installation

Grounding

The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Ground all of this equipment:
Pump: Use a ground wire and clamp as shown in
F
. 1. Remove the ground screw (Z) and insert
IG
through the eye of the ring terminal at end of ground
wire (Y). Fasten the screw back onto the pump and
tighten securely. Connect the other end of the
ground wire to a true earth ground. To order a
ground wire and clamp, order P/N 222011.
Z
F
. 1
IG
Air and fluid hoses: Use only grounded hoses.
Air compressor: Follow manufacturer's recommen-
dations.
Fluid supply container: Follow the local code.
To maintain ground continuity when flushing or
relieving pressure, always hold a metal part of the
fun firmly to the side of a grounded metal waste con-
tainer, then trigger the gun.
307878Y
Models 225773, 225827, 240883,
240884, and 245695
Refer to F
1. Models 225773, 240883, and 245695 only :
2. Models 225827 and 240884 only : Remove the
3. Remove the cover (4) from the pail of lubricant.
4. Secure the cover (4) on the pail with three thumb-
5. Insert the pump riser tube through the top of the
6. Assembly the gun (2b) and hose (2a), and connect
7. Connect the nipple (2d) to the pump air inlet or air
Y
8. Connect the quick-disconnect coupler (2c) to the air
F
IG
. 2 for the following instructions.
IG
Assemble the truck as shown in the parts drawing
on page 13. Secure the truck pail (5) to the truck
base with the pointed hold-down clamps (3c) and
thumb nuts (3d).
fluid outlet adapter included with the pump, and
screw the holster (6) into the pump outlet, using
thread sealant.
Place the pail of lubricant into the truck pail.
screws (A).
cover (4). Lower the pump until it rests on the cover.
the hose to the pump fluid outlet.
regulator (7b) inlet, whichever is applicable.
supply hose.
7b
2b
2c,
2d
4
5
3c, 3d
. 2
Installation
2a
6
A
Model 240883 shown
5