9.5
SITRANS TS500
9.5.1
SITRANS TS500, types 2 and 2N
Type 2, pipe version without process connection
Type 2N, pipe version with screw-in nipple
B
Length of measuring insert
∅d
External diameter of measuring insert
∅D
To
: External diameter of fixing point (6 (0.24))
∅D
To
: External diameter of process connection
∅D3
Internal diameter of protective tube
E
Thread dimension of process connection
H
Height of head
Figure 9-4
Dimensional drawings SITRANS TS500, types 2 and 2N - dimensions in mm (inch)
SITRANS TSinsert/TS100/TS200/TS300/TS500
A5E32897098-01, 09/2013
H
Type Axx: 41 (1.61)
1
Type Bxx: 26 (1.02)
K
Penetration depth
LE
Cable inlet
N
Nominal length
P
Space for process connection
U
Mounting length
X
Extension