Room temperature controllers with 7-day time switch and lcd for heating systems

Advertisement

Use
CE1N3035en
25.09.2003
Room Temperature Controllers
with 7-Day Time Switch and LCD
for heating systems
2-position control with ON/OFF output for heating
Operating Modes: normal operation and energy saving mode
7-Day Time Switch and manual operation
Mains-powered AC 230 V (RDE10) or battery-powered DC 3 V (RDE10.1)
The RDE10... is used for the control of the room temperature in heating systems.
Typical applications:
• Apartments
• Commercial spaces
• Schools
For the control of the following pieces of equipment:
• Thermic valves or zone valves
• Gas or oil burners
• Fans
• Pumps
Siemens Building Technologies
HVAC Products
3
035
RDE10...

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RDE10 Series

  • Page 1 Typical applications: • Apartments • Commercial spaces • Schools For the control of the following pieces of equipment: • Thermic valves or zone valves • Gas or oil burners • Fans • Pumps Siemens Building Technologies CE1N3035en HVAC Products 25.09.2003...
  • Page 2 . The setpoint will then be reset to its initial value the next time auto- matic or manual changeover takes place. When the operating mode selector is set to” “ or “ “, the RDE10... will maintain normal operation or energy saving mode respectively. Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 3 Adapter plate 120 x 120 mm for 4“ x 4“ conduit boxes ARG70 Adapter plate 96 x 120 mm for 2“ x 4“ conduit boxes ARG70.1 Adapter plate for surface wiring 112x130 mm ARG70.2 Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 4 14 Selecting and leaving the setting mode for the switching pattern 15 Setpoint adjustment for energy saving mode 16 Setpoint adjustment for normal operation 17 Button for confirming the switching pattern settings 18 Battery compartment (only with battery-powered versions) Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 5 Reset To reset, first press and hold the button , then press the two buttons simultane- ously for 3 seconds. All individual settings will be reset to their standard values. Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 6 EN 60 730 – 2 - 9 Electromagnetic compatibility Emissions EN 50 081-1 Immunity EN 50 082-1 Safety class II to EN 60730 Pollution class normal Degree of protection of housing IP30 to EN 60529 Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 7: Application Examples

    Live, AC 24 ... 250 V Application examples Room temperature controller with direct Room temperature controller with direct control of a gas-fired floor-standing boiler control of a gas-fired wall-hung boiler Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...
  • Page 8 RDE10... room temperatures controller Safety limit thermostat 3-port valve with manual adjustment Circulating pump Magnetic valve Dimensions Controller 23,8 Baseplate 89,45  2003 Siemens Building Technologies AG Subject to alteration Siemens Building Technologies Room temperature controllers CE1N3035en HVAC Products 25.09.2003...

This manual is also suitable for:

Rde10.1

Table of Contents