Fireplace Specifi Cations - Superior SSDVT-4035CNM Installation Instructions Manual

Direct vent gas fireplace heaters
Table of Contents

Advertisement

FIREPLACE SPECIFICATIONS
Framing Dimensions - Inches (millimeters)
Models
A
SSDVT-3530
35-1/4 (895)
35-1/4 (895)
SSDVR-3530
35-1/4 (895)
35-1/4 (895)
SSDVT-4035
40-1/4 (1022)
40-1/4 (1022)
SSDVR-4035
40-1/4 (1022)
40-1/4 (1022)
Notes
* The Steady State Effi ciency numbers based on
maximum vent confi guration.
Due to Lennox' ongoing commitment to quality,
all specifi cations, ratings and dimensions are
subject to change without notice.
Vent Size
4-1/2" Inner
Co-axial DV Vent Size
7-1/2" Outer
Natural Gas
Models
EnerGuide
Steady
SSDV-3530
55
SSDV-4035
60
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or
frame an opening, 10 " x 10 " (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 19).
Framing Spacers
(Top, Sides & Rear)
H
(Louvered Front Model Shown)
A
Model
SSDVT-3530
SSDVR-3530
SSDVT-4035
SSDVR-4035
Figure 14
B
C
D
N/A
39-3/4 (1010)
21-11/16 (551)
N/A
N/A
44-3/4 (1137)
26-11/16 (678)
N/A
Input (BTU) - MV & Electronic
Natural (NG) & Propane (LP) Gas
Models
Fuel
Input Rate (BTU / HR)
High 23,000
NG
Low 17,500
SSDV-3530
High 23,000
LP
Low 17,500
High 29,000
NG
Low 21,500
SSDV-4035
High 29,000
LP
Low 22,500
Effi ciencies
Propane
AFUE
EnerGuide
Steady
State
State
67
63
60
68
69
65
61
69
G
9
(229)
Top View
3 (76)
E
C
B
D
Front View
A
B
35-1/8 (892)
32-1/8 (816)
40-1/8 (1019)
37-1/8 (943)
**Framing With Square Horizontal Termination SV4.5HT-2
VENT FRAMING -
E
TOP VENT WITH ONE
16"
90• ELBOW
16"
16"
VENT FRAMING -
REAR VENT WITH
16"
NO ELBOWS
B
1/2
AFUE
64
Inches (millimeters)
65
*Co-axial Direct Vent Pipe
Flue - 4-1/2 (114)
Combustion Air - 7-1/2 (190)
*
SSDVR models are
rear vent only
SSDVT models are
top vent only
NOTE - Hood shown as
positioned in louvered
front model.
GAS INLET
(Either Side
and bottom)
(Optional)
ELECTRICAL
INLET Knockout
Requiring A Field
Provided Junction
Box (Either Side)
3 (76)
1-3/8
(35)
Fireplace Dimensions - Inches (millimeters)
C
D
E
19 (483)
29-1/2 (749)
35-1/8 (892)
24 (610)
34-1/2 (876)
40-1/8 (1019)
**Framing should be constructed
of 2 x 4 or larger lumber.
10-1/2
(
)
267
5-1/8
(130)
(178)
5-1/8
D
(130)
C
E
A
A
E is the required framing depth dimension when the
finish material (drywall) thickness is 1/2 in. (13mm).
1/2 (13)
16
(406)
5-1/2
(140)
9-3/8
(238)
F**
2
(53)
Electrical Inlet
2-3/4 x 2 (70 x 51)
Cover Plate
W/Knockout
Right Side View
**Rear vent models only
F
G
(rear vent only)
21-11/16 (551)
24-7/8 (632)
26-11/16 (678)
29-7/8 (759)
7
(178)
12-1/8
(308)
7
12-1/8
(308)
H
12-7/16 (316)
14-15/16 (379)
11