Page 7
EK 60UNV-L Tab. 2 Tab. 3 < Ø < Ø UCD3515 EN 50022 - 35 x 7,5 Klauke DIN Tragschiene EN 50045 - 15x5,5 UCACSR DIN 48204 < Ø 40 mm - auf Anfrage - Tragschiene EN 50022 - 35x7,5 - auf Anfrage - - UCD3575 - “...
Page 8
EK 60UNV-L mm² – 5 mm “ ” 6 - 185 C u, QS 10 - 95 IS, QS 10 - 50 F, QS 1.5 - 16 – 5 mm DIN 46235 DIN 46267 Cu, QS, 6 - 185 Kennzahl DIN 46235 –...
Page 9
EK 60UNV-L mm² – 5 mm “ ” 6 - 300 C u, QS 10 - 150 IS, QS 10 - 70 F, QS 1.5 - 16 5 mm – VA 10 - 50 Ni, QS – 10 - 50 –...
Page 10
EK 60UNV-L mm² 5 mm 4 - 50 C, QS 10 - 240 AE, QS 2 x 4 -2 x 16 AE, 2xQS 10 - 240 AE, QS 2 x 4 - – AE, QS 2 x 16 10 - 240 Aldrey DIN EN 50182 DIN EN 50182, 120-300 mm2...
Instruction Manual EK 60UNV-L Index Description of the electric- hydraulic universal unit Introduction Warranty 3.1 Description of the components Description of the electric-hydraulic The electric-hydraulic crimping unit is a hand held tool universal unit and consists of the following components: Description of the components Table 4 (see Picture 1) Brief description of the important features of...
Instruction Manual EK 60UNV-L A white LED illuminates the working space after ac- 4.1 Operation of the unit tivating the trigger. It automatically switches off 10 First you have to select the right adapter for the type of sec. after releasing the trigger. This feature can be dies you intend to use respectively the cutting blades.
Instruction Manual EK 60UNV-L 4.1.3 Use of the punch adapter Attention The advance (penetration) of the punch into the die must Do not damage the seals of the tool. If the seals be observed carefully. As soon as the sheet metal is pun- are damaged the warranty is invalidated.
Page 18
Instruction Manual EK 60UNV-L Putting out of operation/waste dis- posal This unit is subjected to the scope of the European WEEE (2002/96/EG) and RoHS (2002/95/EEC) directives. Information about this can be found on our home page www.Klauke.com under ‘WEEE & RoHS’. Battery cartridges (page I, pic.
Page 19
EN 60745-1, EN 12100 Teil 1 + 2, EN 294, EN 349, EN 60204-1, EN 28662-1, EN 61000-6-3, EN 61000-6-2, EN 60529, EN 982, EN 1037 ja vastaa säädoksiä 98/37/EU, 2004/108/EU Gustav Klauke GmbH • Auf dem Knapp 46 • D-42855 Remscheid Telefon ++49 +2191-907-0 • Telefax ++49 +2191-907-141 • www.klauke.textron.com...
Page 21
Hr. Michael Radtke Mr. Bürgisser Auf dem Knapp 46 Großmattstr. 19 42855 Remscheid (Germany) CH-8964 Rudolfstetten (Switzerland) 0049- 2191/907-168 0041-56-6492121 0049- 2191/907-243 0041-56-6492141 service@klauke.textron.com info@ferratec.ch FRANKREICH KLAUKE FRANCE POLEN RB Brexim S.A. Mr. Daniel Berrar Mr. Bieniek 16, Rue Saint-Louis Marynin 7a Z.I.
Page 22
Klauke Service SCHWEDEN AGB Service AB ISRAEL Shay A.U., Ltd. Mr. Anders Bennarsten Mr. Shay Flottiljvägen 22 Ind. Zone Kiriat Arieh SE-39241 Kalmar (Sweden) Embar Street 23/25 0046-480-28122 P.O. BOX 10049 0046-480-28165 49222 Petach Tikva (Israel) anders@agbservice.se 00972-3-9233601 00972-3-9234601 ilans@urial-shav.com NORWEGEN Miltronic AS VIETNAM...
Page 23
Klauke Service INDIEN Bishop Electricals Greenlee Textron Mr. Abbishek Rajhashekar Technical Support 64,Avighna, 8th Main, Mr. Tim Kopp Defence Colony, Vinayaka Nagar 4411 Boing Drive Bagalur Cross, yelahanks, Rockford, IL 61109-2932 (USA) Bangalore 560064 (India) 001-800-435-0786 0091-9886115506 001-815- 0091-8026914568 tkopp@greenlee.textron.com servicecentre@bishopelectricals.com...
Need help?
Do you have a question about the Klauke EK 60UNV-L and is the answer not in the manual?