5.7
Checking the interface for the
data terminal (not for BEA-
Euro)
5.8
Checking the hard disk
(if it installed)
38
Select the Interfaces menu and then
Data terminal.
Remove the 10-way Micro-Match plug
from X10 of the control module PCB.
Plug the 10-way shorting plug into X10 of
the control module PCB.
Start the interface test by double-clicking
the mouse or pressing Enter E.
If the interface test is error-free, the
message OK appears in the results box.
If the interface test is unsuccessful, an
error message is displayed.
For example: B0246:1300.
1300 = No shorting plug inserted or pins
3 and 5 of shorting plug not
jumpered.
If any error messages other than this one
are displayed, the control module PCB
must be replaced (Sec. 10.27).
Open the menu Store meiadia test and
then select Hard disk.
The hard disk test is executed automati-
cally.
If the hard disk test is error-free, the
message OK appears in the results box.
If the test is unsuccessful, an error messa-
ge is displayed.
For example: B0246:1300.
1300 = No connection to hard disk
i In such a case of an error either the
printed circuit board 1 688 400 223
and/or 1 682 666 118 also to old
firmware taped or the silicon disc
1 687 370 291 can be defective.