Reference Numbers For Errors In „Communication Error" Group; Reference Numbers In Combination With Awn.modul - Bosch BEA 150 Repair Instructions

Emissions analysis
Table of Contents

Advertisement

8.11.4 Reference numbers for errors in „Communication error" group
No.
Designation
6080 Control module timeout
6081 Control module reception fault
6082 OBDM reception error
6083 Invalid baud rate
6084 Invalid KeyBytes received
6085 Communication terminated
6086 Wrong command to control module
6087 Invalid checksum from control module
6088 Communication ended with error
6089 Invalid data frame (KWP2000)
6090 Control module busy
6091 Service not supported by control module
6100 Faulty dyn. OBD text
6101 Error when allocating memory
6102 Error when opening OBD text file
6105 OBD module transmits unknown
special code
8.12

Reference numbers in combination with AWN.Modul

No.
Designation
7099 No connection to Awn@Chip module
62
Remedy
Run interface test
OBD printed circuit board faulty —> replace
CPU printed circuit board faulty —> replace
Control unit defective.
Run interface test
OBD printed circuit board faulty —> replace
CPU printed circuit board faulty —> replace
Remedy
Check connecting cable for AWN printed circuit board
to CPU printed circuit board using ohmmeter
AWN printed circuit board faulty —> replace
If error persists, notify system administrator
as error may be in the software of the
order processing.
Chapter
5.1 - 5.4
10.30
10.27
5.1 - 5.4
10.30
10.27
Chapter
12.4
10.31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bea 250Bea 350

Table of Contents