81040_5.book Page 26 Monday, February 20, 2006 2:39 PM
26
To fit a power cable:
1. Ensure the intended power source is switched off. If you are using a 12 V bat-
tery, ensure the power cable is not connected to the battery.
2. Run the power cable from the instrument to a suitable 12 V dc power
source.
3. If the cable has not already been trimmed at the power supply end:
• Cut the cable to length and trim back an appropriate amount of the outer
sheath.
• Cut back and insulate the yellow wire.
4. Connect the screen to the power supply 0 V terminal.
5. Connect the red wire via a 3 A over-current circuit breaker to the power
supply +12 V terminal.
ST60 Tridata Instrument Owner's Manual