Test 12a (H261): Zoom in and zoom out of „A to Z‟ map
Subjective
Impairments
H.323
768 kbit/s
BLK
4
BLR
4
CLR
1
JRK
3
Test 12b (H263): Zoom in and zoom out of „A to Z‟ map
Subjective
Impairments
H.323
768 kbit/s
BLK
3
BLR
4
CLR
2
JRK
4
Test 12c (H.264): Zoom in and zoom out of „A to Z‟ map
Subjective
Impairments
H.323
768 kbit/s
BLK
3
BLR
2
CLR
1
JRK
3
Test 13a (H261): Text legibility (% of screen height) at viewing distance approx.
5x screen diagonal
Legibility
H.323
768 kbit/s
20 pt (3.5%)
Yes
16 pt (3%)
Yes
14 pt (2.5%)
No
12 pt (2.3%)
No
2 Mbit/s
3
3
1
2
2 Mbit/s
4 Mbit/s
2
2
2
2
1
1
3
3
2 Mbit/s
4 Mbit/s
2
1
2
2
1
1
2
2
2 Mbit/s
Yes
Yes
No
No