Required Clearance - Siemens SIMATIC HMI Series Operating Instructions Manual

Industrial flat panels v2
Hide thumbs Also See for SIMATIC HMI Series:
Table of Contents

Advertisement

3.1.2.2

Required clearance

The following clearance is required for sufficient self-ventilation around the built-in device:
● At least 15 mm to the right and left of the mounting cutout (in x direction) to allow for
insertion of the mounting clips during installation
● At least 50 mm above and below the mounting cutout (in y direction) for ventilation
● At least 10 mm behind the rear panel of the device (in z direction). The device depth in
the control cabinet is 63.4 mm.
The figure below shows the required clearances when the device is installed in landscape
and portrait format:
x
y
z
Note
Ensure that the maximum ambient temperature is not exceeded when mounting the device
in a cabinet and especially in a closed enclosure.
IFP V2, IFP V2 PRO
Operating Instructions, 08/2019, A5E46641410-AA
Clearance for mounting in landscape format
Clearance for mounting in portrait format
At least 15 mm distance
At least 50 mm distance
At least 10 mm distance
Installing and connecting the device