Technical information
7.10 Interface description
7.10.2

DVI-D

DVI-D, 25-pin socket
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
C5
112
Name
TMDS data2-
TMDS data2+
TMDS Data2 shield
NC
NC
DDC clock (SCL)
DDC data (SDA)
NC
TMDS data1-
TMDS data1+
TMDS Data1 shield
NC
NC
+5 V VCC
GND
HPD
TMDS data 0-
TMDS data 0+
TMDS Data0 shield
NC
NC
TMDS clock shield
TMDS clock+
TMDS clock-
NC
Meaning
DVI data output 2-
DVI data output 2+
Cable shield DVI data output 2
Not assigned
Not assigned
Display Data Channel clock, bidirectional
Display Data Channel data, bidirectional
Not assigned
DVI data output 1-
DVI data output 1+
Cable shield DVI data output 1
Not assigned
Not assigned
+5 V output for DDC
Ground for +5 V
Hot Plug Detect input
DVI data output 0-
DVI data output 0+
Cable shield DVI data output 0
Not assigned
Not assigned
Cable shield DVI clock output
DVI clock output
DVI clock output
Not assigned