Technical information
7.4 Climatic ambient conditions
7.4.3

Operating Conditions

The following information applies to a device installed according to the specifications in these
operating instructions.
The device is designed for weatherproof and stationary operation according to
IEC 60721-3-3.
The device meets the requirements according to IEC 60721-3-3 Class 3K3 with the following
amendments and limitations:
Type of condition
Temperature built-in devices,
Mounting in landscape format
Temperature built-in devices,
Mounting in portrait format
Temperature PRO devices,
Mounting in landscape
format
Temperature Transceiver Unit vertical, interfaces facing
Air pressure, operating
elevation
Relative humidity
Pollutant concentration
Only mounting in landscape format is permitted for PRO devices.
1
Built-in devices: No condensation on the rear of the device,
2
PRO devices: No condensation inside the enclosure,
Transceiver Unit No condensation all-round
Note the information in section "Notes about Usage (Page 30)" and for IFPs the information
on the mounting positions:
● Permitted mounting positions for built-in devices (Page 37)
● Permitted mounting positions for PRO devices (Page 42)
Note
All other system components connected to the device, such as the power supply, must also
be suited to the respective operating conditions.
92
Mounting position
Vertical
Inclined, maximum inclination 35°
Vertical
Inclined, maximum inclination 35°
Vertical
Inclined, maximum inclination 45°
1
downward
1140 ... 795 hPa, corresponds to an elevation of -1000 to 2000 m
10 to 90%, no condensation
SO2: < 0.5 ppm; relative humidity < 60%, no condensation
H
S: < 0.1 ppm; relative humidity < 60%, no condensation
2
Operating Instructions, 08/2019, A5E46641410-AA
Permitted range
0 to 50 °C (15" and 19" device)
0 to 45 °C (22" and 24" device)
0 ... 40 °C
0 ... 40 °C
0 ... 35 °C
0 to 45 °C
0 to 45 °C
0 to 50 °C
2