Current Control (X10), Option - Bosch Rexroth LTH Technical Information Manual

Table of Contents

Advertisement

Available languages

Available languages

56/60
Bosch Rexroth AG
2 Power Unit LTH

2.10.6 Current Control (X10), Option

SUB-D connector, 25-pins, female
Fig. 16:
Pin-No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19-24
25
Table 8:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
| Electric Drives and Controls
13
1
25
14
Signal
Input/Output
(I/O)
PGND
RXD (+)
I
TXD (+)
O
CTS (+)
I
RTS (+)
O
-
GND
-
-
-
+15V
-15V
-
-
RXD (-)
I
TXD (-)
O
CTS (-)
I
RTS (-)
O
-
CAL
I
Description/Function
Shield
Receive data (not inverted)
Send data (not inverted)
PM ready to receive (not inverted)
ST ready to receive (not inverted)
N.C.
Logic reference potential
N.C.
N.C.
N.C.
Supply voltage
Supply voltage
N.C.
N.C.
Receive data (inverted)
Send data (inverted)
PM ready to receive (inverted)
ST ready to receive (inverted)
N.C.
Calibration signal
LTH | 3 609 929 408/2.1