2.9.4 NIO Acknowledgement

When the bolting process (bolting and unbolting) is false, all following power tool starts are ignored and
an error message is output. Further bolting processes are possible only after an NIO acknowledgement.
The acknowledgement of a false bolting process is possible via the "NIO-Quit" key switch or via the pushbutton
of the connected power tool. The NIO acknowledgement of the BMS interface is blocked for manual power tool
operation.
Key switch in center position:
– NIO acknowledgement active on power unit
– NIO acknowledgement by turning key switch to the right
Key switch in left position:
– NIO acknowledgement active on power tool
– NIO acknowledgement by actuating NIO reset button on power tool
NOTE:

2.9.5 IO Sums Counter

The IO sums counter registers all correct bolting processes (IO bolting actions). The counter can be reset
at any time.
Fig. 9:
1 Display of IO bolting actions performed
2 Key of decade 6
3 Reset button (red)
4 Key of decade 5
5 Key of decade 1
6 Buttons for entering of IO bolting actions
7 Indication of IO bolting actions entered
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
| Electric Drives and Controls
A NIO acknowledgement is not possible by a reset or by switching the power unit on/off.
1
2
3
4
IO sums counter
7
6
5
LTH | 3 609 929 408/2.1

Advertisement

Chapters

Table of Contents
loading

Table of Contents