2.7.2 LED-Displays

The operating status of the power unit as well as error messages are displayed by different LEDs on the
front panel.
LED-Display
EXTERN
without designation
USP
NTF
TFVM
BTBVM
BTB
FG
FGI
PV
FI
BL
LI
ST1
ST2
ST3
TF
EC 37
EC 48
Table 2:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Electric Drives and Controls | Bosch Rexroth AG
Color
Significance
green
External program selection (via interface X13)
green
Internal program selection
(LED next to program selector switch)
red
Overvoltage in intermediate circuit of static
frequency converter
red
Power supply defect
red
Temperature error of voltage supply module
(isolation transformer)
green
Voltage supply module ready for operation
green
Power unit ready for operation
green
Release (via interface X8)
green
- Internal release
- No error
- Motor rotating
green
Proportional behaviour of speed regulator
(via interface X8)
red
Current defect (short circuit)
red
Motor blocked
green
Left, in conjunction with step selection
(not active when operated with SE 200)
yellow
Speed step 1 selected (via interface X8)
(not active when operated with SE 200)
yellow
Speed step 2 selected (via interface X8)
(not active when operated with SE 200)
yellow
Speed step 3 selected (via interface X8)
(not active when operated with SE 200)
red
- Temperature error, power unit
- Temperature error, motor
- Power tool cable not connected
green
Motor type EC 37 selected
green
Motor type EC 48 selected