No Display On The Configuration Terminal; Symptom; Solution; Garbled Display On The Configuration Terminal - H3C MSR2600-6-X1-GL Installation Manual

Hide thumbs Also See for MSR2600-6-X1-GL:
Table of Contents

Advertisement

No display on the configuration terminal

Symptom

The configuration terminal does not have display when the router is powered on.

Solution

To resolve the issue:
Verify that the power system is operating correctly.
1.
Verify that the console cable is connected correctly and the connected serial port is the same
2.
as the port configured on the terminal.
Verify that the terminal is configured correctly:
3.
Baud rate—9,600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
Emulation—VT100.
Verify that the console cable is in good condition.
4.
If the issue persists, contact H3C Support.
5.

Garbled display on the configuration terminal

Symptom
The configuration terminal has garbled display when the router is powered on.
Solution
To resolve the issue:
Verify that the Data bits field is set to 8 for the terminal. If the Data bits field is set to 5 or 6,
1.
the terminal displays garbled characters.
If the issue persists, contact H3C Support.
2.

No response from the serial console port

Symptom
The console port on the router is connected to a serial port on a configuration terminal. No boot
information is displayed on the configuration terminal when the router starts up or restarts up.
Solution
To resolve the issue: