Bosch Rexroth BTV 16 Project Planning Manual page 62

Table of Contents

Advertisement

7-16
PC Box
X20 – 230/115 VAC Power
This connection is used for device variants for 230/115 VAC.
Supply
All internally required voltages are generated by the 230/115 VAC power
supply unit.
Note:
Also for devices with a 230/115 VAC voltage connection an
additional voltage of 24 V has to be applied at connector X10,
if the device features 24 V outputs.
CAUTION
The 230/115 VAC connection occurs via a 3-pin inlet connector for non-
heating apparatus on the connector panel. Maximum cable cross section
for the connected cables is 1.5 mm
PE
Fig. 7-21: Pin assignment of the 230/115 VAC connection X20
Parameter
Rated voltage
Power consumption for U
Power consumption for U
Inrush current for U
Inrush current for U
Line-side fuse
Fig. 7-22: Technical data 230/115 VAC connection
The supply voltage must comply with
overvoltage category II! Otherwise the
integrated power supply unit might be
destructed.
⇒ Use an isolating transformer to generate the
230/115 VAC (see following page).
2
.
X20
Value
85 VAC ... 264 VAC auto range
= 230 VAC
0.7 A
N
= 115 VAC
1.4 A
N
30 A cold start 25 °C
= 230 VAC
N
15 A cold start 25 °C
= 115 VAC
N
1.6 A (5x20)
BTV 16/40
Assignment
N1
PE
U2
230V_Buchse.eps
DOK-SUPPL*-BTV16/40***-PR02-EN-P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth btv 40

Table of Contents