Used Standards; Wear Parts; Fig. 4-9: Used Standards; Fig. 4-10: Battery Pack - Bosch Rexroth BTV 16 Project Planning Manual

Table of Contents

Advertisement

BTV 16/40
4.7

Used Standards

4.8

Wear Parts

Wear parts without warranty
DOK-SUPPL*-BTV16/40***-PR02-EN-P
The system components of the operator terminals correspond to the
following standards:
Standard
Meaning
EN 60 204-1
Electrical equipment of machines
EN 50 081-2
Basic technical standard, emitted interference (industrial
environment)
EN 50 082-2
Basic technical standard, noise immunity (industrial
environment)
EN 60 742
Transformer for 24 V power supply unit, protective separation
EN 60 950
Overvoltage category II
EN 61 131
Requirements concerning the 24 V outputs
EN 61 131-2
Requirements concerning the 24 power supply
EN 418
Machine safety, EMERGENCY STOP devices
EN 60 529
Degrees of protection (incl. housings and installation
compartments)
EN 60 068-2-6
Vibration test
EN 60068-2-27
Shock test
.IS.114
X-ray radiation directive according to Official Federal Gazette
Fig. 4-9:
Used standards
Note:
Concerning delivered operator terminals all CE requirements
are fulfilled. After plugging-in extension cards, however, a new
CE test has to be executed.
• The service life of the backlight is limited to a certain number of
operating hours. After this time the backlight will produce only 50 % of
its original brightness. This time differs for the used displays:
• 12": 40,000 hours
• 15": 35,000 hours
• CMOS battery: 5 to 7 years
• Battery pack: The number of charging cycles of the battery pack and
thus, its service life is dependent on the ambient temperature, in which
the battery pack is used.
temperature, in which the operator terminal or the battery pack is
situated, e.g. the internal temperature of the control cabinet or in a
operator panel housing.
Ambient temperature
25 °C
35 °C
45 °C
Fig. 4-10:
Battery pack
If you don't exactly know the conditions, Bosch Rexroth recommends
to exchange the battery pack every 1.5 years.
Technical Data
Ambient temperature is defined as the
Charging cycles
Maintenance interval
4000 cycles
6 years
2000 cycles
3 years
1000 cycles
1.5 years
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth btv 40

Table of Contents