AC and DC cable requirements
M88H_122 (CF) – AC Cable
AC cable
General information on the AC terminal block
The section describes the general technical characteristics of
the AC terminal blocks. The special features which apply to the
installation of the inverter are explained in the following sec-
tions.
The specifications in this section have been
defined by Phoenix Contact. Check if the techni-
cal specifications have changed before starting
installation work; see www.phoenixcontact.com.
NOTICE
Danger of a cable fire.
Bending and twisting causes damage to the
inner structure of the conductor, which leads to
punctiform increase in electrical resistance. This
can result in an overheating of the conductor
and destruction of the insulation.
► When bending and twisting cables or
conductors, always comply with the
manufacturer's instructions.
AC terminal block specifications
Naming
Connection type
Screw thread
Rated current I
N
Rated voltage U
N
Attaching the conductor
Type of attachment
Tightening torque
Specification for copper cable
Min./max. Wire cross-section
Without wire end sleeve
Rigid cable
Flexible cable
with wire end sleeve
Flexible cable (wire end sleeve
without plastic sleeve)
Flexible cable (wire end sleeve with
plastic sleeve)
Stripping length
20
Phoenix Contact UKH 70
Screws with hexagon socket head
M8
96 A
1000 V
M8 screws with hexagon socket
head
8 ... 10 Nm
16 ... 95 mm
25 ... 70 mm
16 ... 70 mm
16 ... 70 mm
24 mm
Quick installation guide for solar inverter M88H RPI883M121300 RPI883M122300 EU V1 EN 5017414200_00 2019-11-07
Specification for aluminum cable
SE
RE
The most important cable types for aluminum cable
sector-shaped, solid conductor
SE
SM-S
sector-shaped, multi-conductor, rigid wires
SM-L
sector-shaped, multi-conductor, (stranded wires)
RE
round, solid conductor
round, multi-conductor, rigid wires
RM-S
RM-L
round, multi-conductor, (stranded wires)
The terminals have been specially developed for direct connec-
tion of sector-shaped solid conductor (SE) aluminum cables:
Conductor cross-section
Stripping length
2
2
2
2
SM-S
RM-S
SE
SM-L
RM-L
50 / 70 mm
2
24 mm
90°