Check whether it is permissible in your country
to utilize sector-shaped, solid aluminum cables.
For all other types of aluminum conductors, Al-Cu compres-
sion joints (e.g. fromKlauke, Elpress or Mecatraction) must be
used; see „Special instructions for the use of aluminum cables",
page 22.
AC cable gland
The inverter has 1 AC cable gland with 1 cable feed-through.
Min./max. Cable diameter
Notes on calculating the cable cross-section
Consider the following factors when calculating the cable cross-
section:
Cable material
Temperature conditions
Cable length
Installation type
Voltage drop
Loss of power in the cable
Always follow the installation regulations for AC cables appli-
cable in your country.
France: Follow the installation instructions of UTE 15-712-1.
This standard contains requirements for minimum cable cross-
sections and to prevent overheating due to high currents.
Germany: Follow the installation instructions of VDE 0100-712.
This standard contains requirements for minimum cable cross-
sections and to prevent overheating due to high currents.
Quick installation guide for solar inverter M88H RPI883M121300 RPI883M122300 EU V1 EN 5017414200_00 2019-11-07
DC cables
The DC plugs for all DC connections are supplied with the
inverter.
If you want to order more or need a different size, see the infor-
mation in the following table.
23.9 ... 51.3 mm
Included in delivery
1)
AC and DC cable requirements
M88H_122 (CF) – DC cable
a
DC connections on the
inverter
DC–
DC+
a
b
mm
mm
2
3-6
4/6
5.5-9
10
5.5-9
3-6
4/6
5.5-9
10
5.5-9
3-6
4/6
5.5-9
b
DC plugs for DC cables
^
Multi-contact
32.0014P0001-UR
32.0016P0001-UR
32.0034P0001-UR
32.0015P0001-UR
32.0017P0001-UR
32.0035P0001-UR
32.0015P0001-UR
32.0017P0001-UR
1)