Replace The Air Filter Assembly - Hypertherm XPR300 Replacement Part Procedures

Table of Contents

Advertisement

Replace the air filter assembly

See Core, VWI, and OptiMix gas connect console manifold side on
page 131 for location and part number.
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. Remove the gas pressure from the cutting system.
c. Remove the top panel.
See Gas connect console panels on page 87.
Keep all nuts and screws that you remove.
2. Disconnect the hoses
from the
push-to-connect fittings.
See How to use
push-to-connect fittings
on page 66.
3. Use a 3 mm,
hexagonal-key wrench to
remove the 2 screws.
4. Remove the air filter
assembly.
5. Remove the 2 fittings.
6. Install the 2 fittings onto
the new air filter
assembly.
7. Use the 2 screws to
install the air filter
assembly.
8. Connect the hoses to the push-to-connect fittings. See How to use push-to-connect fittings on
page 66.
9. Install the top panel.
XPR300
Field Service Bulletin
809970
2
Gas Connect Consoles
77